PAGE 14 of 24 VR4K (4+1) SERIES TECHNICAL MANUAL VER1.1
INSTALLATION
The wiring diagram towards the back of this manual should be followed carefully. Heavy
duty conductors on wiring diagrams are shown heavily outlined, these wires should be
doubled up.
- Check that all components are free from damage before installing (Do not proceed with installation in the
event of damage).
- Keep all packaging away from children.
- Do not obstruct the ventilation openings or slots on any of the devices.
- All connections to mains voltages must be made to the current national standards (IEE Wiring
regulations)
- Install an appropriate fused spur or isolation switch to isolate the mains.
- Isolate the mains before carrying out any maintenance work on the system.
- All intercom and access control cables must be routed separately from the mains.
- When the panel is mounted on an uneven surface, use additional sealant to protect from water ingress.
Lock release back EMF protection : A capacitor must be fitted across the terminals on
an AC powered lock release
and a diode must be fitted across the terminals on a DC
powered lock release as shown in the diagrams below to suppress back EMF voltages.
LOCK RELEASE
12V AC
~~
0.1uF capacitor
+
-
1N4002
+
-
12V DC
LOCK RELEASE
DIODE